Transformer calculator

Enter the primary voltage and turns, then either the secondary turns or the secondary voltage you want, and the load in VA. The calculator uses the ideal transformer equations: voltage follows the turns ratio and current follows its inverse.

Find
V
VA
Secondary voltage11.5 V
Turns ratio Np : Ns
20
Primary current
0.4348 A
Secondary current
8.6957 A
Turns per volt
4.3478

Runs in your browser: nothing you enter is sent anywhere.

How to use it

  1. Choose what to find: the secondary voltage (you know both turn counts) or the secondary turns (you know the voltage you want).
  2. Enter the primary voltage and the number of primary turns.
  3. Enter the secondary turns or the target secondary voltage, and the load in VA.
  4. Read the result, the turns ratio, both currents and the turns per volt.

The ideal transformer equations

  • Voltage: Vs = Vp × Ns / Np.
  • Turns: Ns = Np × Vs / Vp.
  • Turns ratio: a = Np / Ns = Vp / Vs.
  • Currents: Ip = S / Vp and Is = S / Vs, so Ip / Is = Ns / Np.
  • Turns per volt: Np / Vp.

The ideal model has no winding resistance, no leakage and no magnetising current, and input power equals output power.

Worked example

A 230 V primary with 1,000 turns and a 50-turn secondary: a = 1,000 ÷ 50 = 20, Vs = 230 ÷ 20 = 11.5 V. With a 100 VA load, Ip = 100 ÷ 230 = 0.4348 A and Is = 100 ÷ 11.5 = 8.6957 A. The core takes 1,000 ÷ 230 = 4.3478 turns per volt.

To get 12 V from a 230 V primary of 1,150 turns: Ns = 1,150 × 12 ÷ 230 = 60 turns, ratio 19.1667.

Tips and common mistakes

  • Use the same kind of voltage on both sides: RMS with RMS. A 12 V RMS winding rectified and smoothed charges a capacitor to about its peak, 12 × √2 ≈ 17 V, minus the diode drops.
  • VA is not watts. Transformers are rated in VA because heating depends on current, whatever the power factor of the load.
  • Allow for losses. Real voltage under load is a few percent lower than the ideal figure, more in small transformers.

Frequently asked questions

What is the turns ratio of a transformer?

It is the number of primary turns divided by the number of secondary turns, Np / Ns. In an ideal transformer the voltages have the same ratio, Vp / Vs = Np / Ns. A ratio above 1 steps the voltage down, below 1 steps it up.

How do I find the secondary current?

Divide the load in volt-amperes by the secondary voltage: Is = S / Vs. A 100 VA load on an 11.5 V winding draws 100 ÷ 11.5 = 8.6957 A. The primary current is S / Vp, smaller by the turns ratio in a step-down transformer.

Why does a real transformer give a higher voltage with no load?

The winding resistance and leakage inductance drop some voltage when current flows. Small transformers are often wound with a few extra secondary turns so that the rated voltage appears at full load; the off-load voltage is then higher. This calculator ignores those losses.

What is turns per volt used for?

When you rewind a transformer, turns per volt (Np / Vp) tells how many turns each volt of any winding needs on that core. Multiply it by the voltage you want to get the turn count of a new winding.

More in Unit converters